Simplex (4098-9714) TrueAlarm Photoelectric Smoke Sensor 0742444CN

$69.00

SKU: 4098-9714

TrueAlarm Analog Sensor

Quantity Pricing Below

Simplex 4098-9714 TrueAlarm Photoelectric Sensor / Detector  0742444CN

The Simplex 4098-9714 TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing.  Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration.  Sensitivity is selected and monitored at the fire alarm control panel.

The sensor head design provides 360° smoke entry for optimum response to smoke from any direction.  A built-in screen keeps insects from entering the smoke chamber.  Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow.

This photoelectric detector can be used with the 4010 and 4100U series control panels from Simplex. It also is compatible with the 4008, 4020, 4210, and 4100 series, as well as with 2120 TrueAlarm CDT’s. This high-quality sensor will ensure your system is always in proper working order, so place your order today and we’ll ship it to you immediately.

For more information about this Simplex replacement sensor, contact the Life Safety Consultants team at (888) 557-0558, or email us at :  sales@lifesafetycom.com

 

Additional information

Weight .025 lbs
Dimensions 4 × 4 × 2 in
Condition

New

Part Type

Analog, Photoelectric, Sensor, Smoke Detector

Manufacturers

Simplex

 

 

 

 

 

Features

  • TrueAlarm analog sensing provides:
    • Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications
  • For use with the following Simplex® products:
    • 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details)
    • 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation
  • Fire alarm control panel provides:
    • Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection
    • Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity
    • Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot
    • Ability to display and print detailed sensor information in plain English language
  • Photoelectric smoke sensors provide:
    • Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3)
  • Heat sensors provide:
    • Three fixed temperature sensing thresholds: 135° F, 155° F and 190° F
    • Rate-of-rise temperature sensing
    • Utility temperature sensing
    • Listed to UL 521 and ULC-S530
  • General features:
    • Operation is for ceiling or wall mounting
    • Listed to UL 268 and ULC-S529
    • Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted
    • Designed for EMI compatibility
    • Magnetic test feature is provided
    • Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator
  • Additional base reference:
    • For isolator bases, refer to data sheet S4098-0025
    • For sounder bases, refer to data sheet S4098-0028
    • For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address)